Skip to content Skip to navigation

PRA200 - Residual Gas Analyzer, D05001201

Part Number: D05001201

PRA - Residual Gas Analyzer

The Edwards RGAs are quadrupole mass spectrometers with a high performance analyser tube consisting of the ion source, the quadrupole filter and the detector.

 

We offer two variants, giving you the perfect choice for your various needs.

 

PRA: Our Primary Residual Gas Analyser is the perfect solution for all “basic” applications and processes, to do quick and convenient analysis.

 

WRA: Our Wide Range Residual Gas Analyser, for advanced and more demanding processes and analysis allowing higher analyzer temperatures and bake out temperatures of up to 300°C. To match advanced needs, the WRA offers a better sensitivity to detect even the smallest traces of molecules.

Features and Benefits

  • PRA – the perfect starting point for “basic” applications and processes
  • WRA – 1-200 or 1-300 amu, for more demanding processes and analysis
  • Total pressure measurement for full process control
  • Dual filament for highest reliability and up-time
  • Ethernet protocol
  • Degas function
  • Protection of ion source and EM
  • Customer replaceable parts

General Product Information

Connection Inlet Flange DN 40 CF (2.75")
Weight 2.60
Power Supply Voltage DC 24V
Dimension Length 0.200
Dimension Height 0.132
Dimension Width 0.137
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.

Environmental Conditions

Temperature Ambient Operation Max 313.15
Temperature Ambient Operation Min 283.15
Temperature Ambient Storage Max 313.15

Classification

Classification Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Ultra High Vacuum: 1·10⁻⁷ - 1·10⁻¹¹ mbar
Classification Principle of Measurement Mass spectrometer - Quadrupole + Faraday cup

Material of Construction

Material Filament Platinum/Iridium

Performance Data

RGA Sensitivity Faraday Cup 1.000 × 10⁻⁵ ??
RGA Pressure Detectable Partial Faraday Cup Min 1.000 × 10⁻⁸
RGA Mass range 1-200 amu
RGA Pressure Operating Max 0.010

Operation Conditions - Limitations

Temperature Baking Max (Elec. Removed) 523.15
Temperature Baking Max 523.15
Temperature RGA Analyser Max 393.15
Product Title Part Number Price Add to cart
PRA Ion Source, D05001013 D05001013 -
PRA100/200 analyzer tube, D05001016 D05001016 -